WOODDRYER SYSTEM specification sheet.

Temperature and Relative humidity sensor.

Wooddryer System pionered the used of Relative Humidity sensing in dry kilns more than two decades ago. As the sensor technology has advanced together with computer technology we have been on the leading edge of designing and building the most versitile control system, without making the kiln operators life harder.

Reason to switch to a Temp/RH sensor:

  • Serious mis-reading from dried wet wick on the wet bulb.
  • No more messy water bath in side the kiln.

Wooddryer System type: WSUS-SNSR-RHT.

This sensor is very well suited for use in low to medium temperature hardwood
kilns, but has not been designed for use in high temperature pine kilns.
For this purpuse use our remove Temp/RH sensor.

Tempeature specifications:

Output range:
0-100C or 32-212F
Output signal:
4-20mA DC liniar signal (2-wire technology)
Accuracy:
+/- 0.3C or +/- 0.6F
Operating temperature:
-20-60C or 0-140F.
Power supply:
8-30VDC (35VDC max).
Supply influence
0.01C/Volt or 0.02F/Volt Typ.
Relative Humidity specifications:

Output Range:
0-100% RH
Output Signal:
4-20mA DC liniar signal (2-wire technology)
Accuracy:
+/-2% from 5-95% RH
(equal to 0.5C or 1F on your wet bulb at 50C/120F)
Operating temperature:
-20-60C or 0-140F.
Power supply:
8-30VDC (35VDC max)
Supply influence
0.01%/Volt Typ.